Phasor Dynamics
Root elements
Name |
Value |
|---|---|
|
Path to the system model file[1] |
|
Monitor output time interval for recorded simulation results (default: 0, no intermediate monitoring) |
|
A floating-point value for max time |
|
Relative solver tolerance (default: 1.0e-7) |
|
Absolute solver tolerance override (default: 1.0e-9) |
|
Fixed solver time step size, or 0 for adaptive stepping (default: 0) |
|
Maximum number of solver time steps, 0 for the IDA default, or a negative number for unlimited steps (default: 0) |
|
Maximum IDA integration method order from 1 to 5 (default: 5; fixed stepping is capped at 2) |
|
IDA consistent initial condition calculation type; one of { “y”, “ya_ydp” } (default: “ya_ydp”) |
|
An array of event groups (see Events below) |
|
Path to output (CSV) file (optional) |
|
A string containing the name of the case (optional) |
|
One of { “relative” (default), “absolute” } |
|
A floating-point value for highest allowable total error (default: 1.0e-4) |
|
A floating-point value for the smallest value at which to scale relative error (default: machine epsilon for double-precision) |
Events
Each event group describes a system event that occurs at a given time point
Name |
Value |
|---|---|
|
A floating point value for time event occurs |
|
Event type (one of { “fault_on”, “fault_off”, “in_service”, “out_of_service” }) |
|
Number of the faulted bus (omitted for |
|
Fault resistance in per unit (required for “fault_on”) |
|
Fault reactance in per unit (required for “fault_on”) |
|
|